Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Stud Health Technol Inform ; 294: 68-72, 2022 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-35612018

RESUMO

BACKGROUND: Artificial intelligence (AI) in medicine is a very topical issue. As far as the attitudes and perspectives of the different stakeholders in healthcare are concerned, there is still much to be explored. OBJECTIVE: Our aim was to determine attitudes and aspects towards acceptance of AI applications from the perspective of physicians in university hospitals. METHODS: We conducted individual exploratory expert interviews. Low fidelity mockups were used to show interviewees potential application areas of AI in clinical care. RESULTS: In principle, physicians are open to the use of AI in medical care. However, they are critical of some aspects such as data protection or the lack of explainability of the systems. CONCLUSION: Although some trends in attitudes e.g., on the challenges or benefits of using AI became clear, it is necessary to conduct further research as intended by the subsequent PEAK project.


Assuntos
Inteligência Artificial , Médicos , Atitude , Atenção à Saúde , Humanos , Assistência ao Paciente
2.
PLoS One ; 16(10): e0239021, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34610020

RESUMO

Longitudinal imaging studies are crucial for advancing the understanding of brain development over the lifespan. Thus, more and more studies acquire imaging data at multiple time points or with long follow-up intervals. In these studies changes to magnetic resonance imaging (MRI) scanners often become inevitable which may decrease the reliability of the MRI assessments and introduce biases. We therefore investigated the difference between MRI scanners with subsequent versions (3 Tesla Siemens Verio vs. Skyra) on the cortical and subcortical measures of grey matter in 116 healthy, young adults using the well-established longitudinal FreeSurfer stream for T1-weighted brain images. We found excellent between-scanner reliability for cortical and subcortical measures of grey matter structure (intra-class correlation coefficient > 0.8). Yet, paired t-tests revealed statistically significant differences in at least 67% of the regions, with percent differences around 2 to 4%, depending on the outcome measure. Offline correction for gradient distortions only slightly reduced these biases. Further, T1-imaging based quality measures reflecting gray-white matter contrast systematically differed between scanners. We conclude that scanner upgrades during a longitudinal study introduce bias in measures of cortical and subcortical grey matter structure. Therefore, before upgrading a MRI scanner during an ongoing study, researchers should prepare to implement an appropriate correction method for these effects.


Assuntos
Substância Cinzenta/fisiologia , Adulto , Feminino , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Substância Branca/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...